FOCUS ON EC FAN ONLY
PBM FOCUS ON EC FAN ONLY. Certificate: CE,UL,ROHS; Supply Ability: 100,000 pcs per year; MOQ: 1~100 pcs based on EXW price; 100 pcs above based on FOB price.
General Characters
1-1 |
Rated Voltage |
230 VAC |
1-2 |
Frequency |
50/60 Hz |
1-3 |
Operating Voltage |
184~270 VAC |
1-4 |
Rated Speed | 3600 RPM |
1-5 |
Input Current |
2.5 A |
1-6 |
Input Power |
550 W |
1-7 |
Air Flow |
1618.38 CFM / 2750 M³/H |
1-8 |
Static Pressure |
1.32 inH2O / 330 Pa |
1-9 |
Acoustical Noise |
85 dB(A) |
1-10 |
Life Expectance |
50,000 Hours(L10) At 40℃ room, humidity 15%~65%RH. |
1-11 |
Insulation Class |
Class F |
1-13 |
Motor Protection |
Locked rotor protection Polarity protection Automatic restart capability |
1-14 |
Speed Control |
Control input 0~10VDC / PWM |
1-15 |
Protection Type |
IP55 |
1-17 |
Signal Output |
FG (Frequency Generator) |
Mechanical Characters
2-1 |
Dimension |
Ø252 mm X 210.5 mm (see dimension drawing) |
2-2 |
Material of Impeller |
Aluminium sheet |
2-3 |
Number of Blades |
8 |
2-4 |
Bearing System |
NMB ball bearing |
2-5 |
Lead Wire |
AC (AWG18#),DC (AWG24#) |
Environmental Characters
3-1 |
Operating Temperature |
-25℃ to 60℃ |
3-2 |
Storage Temperature |
-40℃ to 75℃ |
3-3 |
Operating Humidity |
5% to 90% RH |
3-4 |
Storage Humidity |
5% to 95% RH |
Performance Curve
Testing Condition:
Input Voltage----Operating voltage (230VAC/50Hz)
Temperature-----Room temperature
Humidity---------65%RH
Outline Drawing
Note:
1.Connection line: AC(5×AWG18#),DC(6×AWG24#)
2.AC: Brown=Live Line,Black=Null Line,Green & Yellow=Protecting Earthing,White=NC,Gray=COM;
3.DC: Red=Voltage Output +10VDC, Yellow=0-10VDC/PWM, Blue=GND, White=Tach output, Brown=RSA, Gray=RSB ;
By continuing to use the site you agree to our privacy policy Terms and Conditions.